Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/29321
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yılmaz, E. | - |
dc.contributor.author | McGarrigle, A. M. | - |
dc.contributor.author | Vasovic, N. | - |
dc.contributor.author | Yeğen, Dinçer | - |
dc.contributor.author | Jaksic, Aleksandar | - |
dc.date.accessioned | 2022-11-02T08:17:16Z | - |
dc.date.available | 2022-11-02T08:17:16Z | - |
dc.date.issued | 2017-06-08 | - |
dc.identifier.citation | Yılmaz, E. vd. (2017). ''Investigation of RadFET response to X-ray and electron beams''. Applied Radiation and Isotopes, 127, 156-160. | en_US |
dc.identifier.issn | 0969-8043 | - |
dc.identifier.uri | https://doi.org/10.1016/j.apradiso.2017.06.004 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0969804316304122 | - |
dc.identifier.uri | http://hdl.handle.net/11452/29321 | - |
dc.description.abstract | The irradiation response of Radiation Sensing Field Effect Transistor (RadFET), also known as MOSFET/pMOS dosimeter, to high energy X-rays and electron beams was investigated. The threshold voltages before and after irradiation were measured and the trap densities in the gate oxide and oxide/silicon interface of the RadFETs are evaluated. The RadFETs were irradiated with 6 MV X-rays, and 10 and 18 MeV electron beams emitted from a Linear accelerator (LINAC). Linear and non-linear fits to experimental results showed that after an initial linear response up to several Gy, deviation from the linearity occurred due to electric field screening by the radiation induced oxide trapped charges. The radiation-induced fixed traps (FTs) and switching traps (STs) were analysed and the FT density was found to be higher than the ST density for all beam types and doses. The radiation response, fading characteristics, and variation of the trapped charges of the RadFETs showed similar behaviour in tests. | en_US |
dc.description.sponsorship | Abant İzzet Baysal Üniversitesi- AIBU - BAP. 2015.03.02.954 - BAP. 2014.03.02.705 | tr_TR |
dc.description.sponsorship | Türkiye Cumhuriyeti Kalkınma Bakanlığı - 2012 K 120360 - 2016K121110 | tr_TR |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Nuclear science & technology | en_US |
dc.subject | Radiology, nuclear medicine & medical imaging | en_US |
dc.subject | Oxide traps | en_US |
dc.subject | Irradiation | en_US |
dc.subject | Sensitivity | en_US |
dc.subject | Charge | en_US |
dc.subject | Bias | en_US |
dc.subject | Electric fields | en_US |
dc.subject | Electron beams | en_US |
dc.subject | Irradiation | en_US |
dc.subject | Linear accelerators | en_US |
dc.subject | MOS devices | en_US |
dc.subject | Radiation | en_US |
dc.subject | Threshold voltage | en_US |
dc.subject | Electric field screening | en_US |
dc.subject | Fading characteristics | en_US |
dc.subject | High energy X ray | en_US |
dc.subject | Oxide trapped charge | en_US |
dc.subject | Radiation response | en_US |
dc.subject | Radiation-induced | en_US |
dc.subject | Radiation-sensing | en_US |
dc.subject | Switching trap (STs) | en_US |
dc.subject | Field effect transistors | en_US |
dc.title | Investigation of RadFET response to X-ray and electron beams | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000407535600024 | tr_TR |
dc.identifier.scopus | 2-s2.0-85020637920 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen-Edebiyet Fakültesi/Fizik Bölümü. | tr_TR |
dc.contributor.orcid | 0000-0002-1836-7033 | tr_TR |
dc.identifier.startpage | 156 | tr_TR |
dc.identifier.endpage | 160 | tr_TR |
dc.identifier.volume | 127 | tr_TR |
dc.relation.journal | Applied Radiation and Isotopes | en_US |
dc.contributor.buuauthor | Kahraman, Ayşegül | - |
dc.contributor.researcherid | AAH-6441-2021 | tr_TR |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.relation.collaboration | Sanayi | tr_TR |
dc.relation.collaboration | Yurt dışı | tr_TR |
dc.identifier.pubmed | 28622597 | tr_TR |
dc.subject.wos | Chemistry, inorganic & nuclear | en_US |
dc.subject.wos | Nuclear science & technology | en_US |
dc.subject.wos | Radiology, nuclear medicine & medical imaging | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.pubmed | PubMed | en_US |
dc.wos.quartile | Q4 | en_US |
dc.wos.quartile | Q3 (Chemistry, inorganic & nuclear) | en_US |
dc.contributor.scopusid | 47161190600 | tr_TR |
dc.subject.scopus | Dosimeters; MOSFET; Radiation | en_US |
dc.subject.emtree | Oxide | en_US |
dc.subject.emtree | Silicon | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Controlled study | en_US |
dc.subject.emtree | Density | en_US |
dc.subject.emtree | Dosimeter | en_US |
dc.subject.emtree | Electric field | en_US |
dc.subject.emtree | Electric potential | en_US |
dc.subject.emtree | Electron accelerator | en_US |
dc.subject.emtree | Electron beam | en_US |
dc.subject.emtree | Priority journal | en_US |
dc.subject.emtree | Radiation dose | en_US |
dc.subject.emtree | Radiation measurement | en_US |
dc.subject.emtree | Radiation response | en_US |
dc.subject.emtree | Radiation sensing field effect transistor | en_US |
dc.subject.emtree | Radiosensitivity | en_US |
dc.subject.emtree | X irradiation | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.