Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/29887
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.date.accessioned | 2022-12-14T13:22:51Z | - |
dc.date.available | 2022-12-14T13:22:51Z | - |
dc.date.issued | 2014-06-08 | - |
dc.identifier.citation | Yamankaradeniz, N. vd. (2016). "Performance analysis of a re-circulating heat pump dryer". Thermal Science, 20(1), 267-277. | en_US |
dc.identifier.issn | 0354-9836 | - |
dc.identifier.issn | 2334-7163 | - |
dc.identifier.uri | https://doi.org/10.2298/TSCI130426069Y | - |
dc.identifier.uri | http://www.doiserbia.nb.rs/Article.aspx?ID=0354-98361400069Y#.Y4DHQn1ByM8 | - |
dc.identifier.uri | http://hdl.handle.net/11452/29887 | - |
dc.description.abstract | A re-circulating heat pump dryer (HPD) system was designed, constructed and tested at steady-state and transient conditions. Refrigerant 134a was used as a refrigerant in this system. The tests were performed to observe behavior of HPD system. So, changes of temperature and relative humidity of drying air through the dryer and heat pump operating temperatures were observed during the drying process and effects of by-pass air ratio (BAR) on the system's parameters as system performance and specific moisture extracted ratio (SMER) at steady-state were investigated. The HPD system was also tested to investigate temperatures and relative humidity changes of drying air during drying process on the system's parameters depend on time. Airflow rate circulated through the HPD system was 554 m(3)/h during the all tests. According to test results, the system's parameters did not change up to 40% of BAR. Then the coefficient at performance (COP) and SMER values were decreased after 40% of BAR. While SMER values changed between 1.2 and 1.4, COPsys changed between 2.8 and 3.3 depend on BAR. As well as during the drying process, the COP and SMER values were also affected and decreased depend on time. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Vinca Inst Nuclear | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Atıf Gayri Ticari Türetilemez 4.0 Uluslararası | tr_TR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Thermodynamics | en_US |
dc.subject | Drying | en_US |
dc.subject | Dryer | en_US |
dc.subject | Heat pump | en_US |
dc.subject | By-pass air ratio | en_US |
dc.subject | Heat pump assisted dryer | en_US |
dc.subject | Simulation-model | en_US |
dc.subject | System | en_US |
dc.subject | Dryers (equipment) | en_US |
dc.subject | Heat pump systems | en_US |
dc.subject | Pumps | en_US |
dc.subject | Refrigerants | en_US |
dc.subject | %moisture | en_US |
dc.subject | Air ratio | en_US |
dc.subject | By pass | en_US |
dc.subject | By-pass air ratio | en_US |
dc.subject | Drying process | en_US |
dc.subject | Heat pump dryer system | en_US |
dc.subject | Heat pumps | en_US |
dc.subject | Systems parameters | en_US |
dc.title | Performance analysis of a re-circulating heat pump dryer | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000373314400025 | tr_TR |
dc.identifier.scopus | 2-s2.0-84963620299 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Teknik Bilimler Meslek Yüksekokulu/Elektrik ve Enerji Bölümü. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik ve Mimarlık Fakültesi/Makine Mühendisliği Bölümü. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Orhangazi Meslek Yüksekokulu. | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Bölümü. | tr_TR |
dc.relation.bap | M-2008/63 | tr_TR |
dc.contributor.orcid | 0000-0001-8647-4861 | tr_TR |
dc.contributor.orcid | 0000-0001-5027-9458 | tr_TR |
dc.identifier.startpage | 267 | tr_TR |
dc.identifier.endpage | 277 | tr_TR |
dc.identifier.volume | 20 | tr_TR |
dc.identifier.issue | 1 | tr_TR |
dc.relation.journal | Thermal Science | en_US |
dc.contributor.buuauthor | Yamankaradeniz, Nurettin | - |
dc.contributor.buuauthor | Sökmen, K. Furkan | - |
dc.contributor.buuauthor | Coşkun, Salih | - |
dc.contributor.buuauthor | Kaynaklı, Ömer | - |
dc.contributor.buuauthor | Pastakkaya, Bilsay | - |
dc.contributor.researcherid | R-5685-2016 | tr_TR |
dc.contributor.researcherid | AAA-1753-2021 | tr_TR |
dc.contributor.researcherid | R-2401-2018 | tr_TR |
dc.subject.wos | Thermodynamics | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q3 | en_US |
dc.contributor.scopusid | 26645227400 | tr_TR |
dc.contributor.scopusid | 26645227400 | tr_TR |
dc.contributor.scopusid | 26644674500 | tr_TR |
dc.contributor.scopusid | 8387145900 | tr_TR |
dc.contributor.scopusid | 56257775400 | tr_TR |
dc.subject.scopus | Drying Apparatus; Drying; Exergy | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Yamankaradeniz_vd_2016.pdf | 269.92 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License