Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız: http://hdl.handle.net/11452/30580
Başlık: Thermal assessment of laminar flow liquid cooling blocks for LED circuit boards used in automotive headlight assemblies
Yazarlar: Aktaş, Mehmet
Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.
Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Otomotiv Mühendisliği Bölümü.
0000-0003-2113-4510
0000-0002-7746-2014
Kılıç, Muhsin
Sevilgen, Gökhan
57202677637
24722267300
Anahtar kelimeler: Energy & fuels
Automotive headlight
CFD
LED chip
Junction temperature
Liquid cooling
Finned plate
Laminar flow
Heat-transfer
System
Management
Design
Cooler
Sink
Cooling
Drops
Flow rate
Headlights
Laminar flow
Light emitting diodes
Liquids
Mass transfer
Numerical models
Pressure drop
Thermal management (electronics)
Timing circuits
Conjugate heat transfer
High-power light-emitting diodes
Junction temperatures
LED chips
Liquid cooling
Nusselt number correlation
Three-dimensional numerical modeling
Volumetric heat generation
Computational fluid dynamics
Yayın Tarihi: 3-Mar-2020
Yayıncı: MDPI
Atıf: Kılıç, M. vd. (2020). "Thermal assessment of laminar flow liquid cooling blocks for LED circuit boards used in automotive headlight assemblies". Energies, 13(5).
Özet: This research work presents a comparative thermal performance assessment of the laminar flow cooling blocks produced for automotive headlight assembly using a high power Light Emitting Diode (LED) chip. A three-dimensional numerical model with conjugate heat transfer in solid and fluid domains was used. Laminar flow was considered in the present analysis. The validation of the numerical model was realized by using the measured data from the test rig. It was observed that substantial temperature variations were occurred around the LED chip owing to volumetric heat generation. The cooling board with lower height performs better thermal performance but higher pressure drop for the same mass flow rates. The cooling board with the finned cover plate performs better thermal performance but results in an increased pressure drop for the same mass flow rates. Increasing the power of the LED results in higher temperature values for the same mass flow rates. The junction temperature is highly dependent on the mass flow rates and LED power. It can be controlled by means of the mass flow rate of the coolant fluid. New Nusselt number correlations are proposed for laminar flow mini-channel liquid cooling block applications.
URI: https://doi.org/10.3390/en13051202
https://www.mdpi.com/1996-1073/13/5/1202
http://hdl.handle.net/11452/30580
ISSN: 1996-1073
Koleksiyonlarda Görünür:Scopus
Web of Science

Bu öğenin dosyaları:
Dosya Açıklama BoyutBiçim 
Kılıç_vd_2020.pdf4.89 MBAdobe PDFKüçük resim
Göster/Aç