Please use this identifier to cite or link to this item:
http://hdl.handle.net/11452/30594
Title: | Behavioral response of weaned pigs during gas euthanasia with CO2, CO2 with butorphanol, or nitrous oxide |
Authors: | Rault, Jean-Loup Gates, Richard Lay, Donald C. Bursa Uludağ Üniversitesi/Veteriner Fakültesi/Zootekni Anabilim Dalı. 0000-0002-9018-3511 Çavuşoğlu, Enver 56541296300 |
Keywords: | Agriculture Veterinary sciences Zoology Gas flow rate Sus scrofa Swine Euthanasia Welfare Carbon-dioxide Welfare implications Aversion Mixtures |
Issue Date: | 27-Apr-2020 |
Publisher: | MDPI |
Citation: | Çavuşoğlu, E. vd. (2020). "Behavioral response of weaned pigs during gas euthanasia with CO2, CO2 with butorphanol, or nitrous oxide". Animals, 10(5). |
Abstract: | Simple Summary Pig farmers are forced to euthanize a significant number of pigs due to injuries, hernias, or unthriftiness. The majority of pigs are euthanized using carbon dioxide gas asphyxiation. However, the humaneness of carbon dioxide is being increasingly questioned. An alternative is the use of nitrous oxide gas. We conducted this study to compare the euthanasia of young pigs using nitrous oxide or carbon dioxide. In addition, we tested the administration of a pain relief drug prior to carbon dioxide exposure to determine if we could eliminate behaviors indicative of pain. Pigs became unable to control their muscle movement, breathed heavily, and lost posture at the same time regardless of treatment. Pigs exposed to both gases showed heavy breathing and open-mouth breathing prior to losing posture. However, pigs exposed to carbon dioxide made more escape attempts but fewer squeals than pigs exposed to nitrous oxide. Administration of pain relief prior to exposure to carbon dioxide did not alter behaviors indicative of pain. The findings are inconclusive as to whether using nitrous oxide is significantly better than using carbon dioxide, but the results show that its use is just as effective, and possibly more humane. Abstract The swine industry is often forced to euthanize pigs in the first few weeks of life due to injuries, hernias, or unthriftiness. The majority of pigs are euthanized using carbon dioxide (CO2) gas asphyxiation but concerns as to the humaneness of CO2 are increasing. This study compared the euthanasia of weaned pigs using N2O (N2O; n = 9) or CO2 (n = 9), at 50% and 25% min(-1) exchange rate, respectively. In addition, we administered an analgesic prior to euthanasia with CO2 (CO2B) exposure as a third treatment (n = 9) to elucidate behaviors indicative of pain. Pigs in the CO2 and N2O treatments lost posture at similar times (latency of 145.0 +/- 17.3 and 162.6 +/- 7.0 s respectively, p > 0.10), while the CO2B treatment pigs lost posture the soonest (101.2 +/- 4.7 s, p < 0.01). The pigs in the CO2B treatment made more escape attempts than the CO2 or N2O pigs (16.4 +/- 4.2, 4.7 +/- 1.6, 0.3 +/- 0.2, respectively; p < 0.0004). However, pigs in N2O squealed more often than either the CO2 or CO2B pigs (9.0 +/- 1.6, 2.8 +/- 1.2, 1.3 +/- 0.6, respectively, p < 0.001). Given the similar time to loss of posture and shorter time displaying open mouth breathing, N2O may cause less stress to pigs; however, the greater number of squeals performed by these pigs suggests the opposite. It was not apparent that any behavior measured was indicative of pain. In conclusion, N2O applied at a 50% min(-1) flow rate can be an alternative to CO2 for pig euthanasia. |
URI: | https://doi.org/10.3390/ani10050787 https://www.mdpi.com/2076-2615/10/5/787 http://hdl.handle.net/11452/30594 |
ISSN: | 2076-2615 |
Appears in Collections: | PubMed Scopus Web of Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Çavuşoğlu_2020_vd.pdf | 537.22 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License