Bu öğeden alıntı yapmak, öğeye bağlanmak için bu tanımlayıcıyı kullanınız:
http://hdl.handle.net/11452/30602
Başlık: | Development of a new solid phase extraction method for sensitive determination of some carbamate pesticides in water using poly(EGDMA-MATrp) microbeads |
Yazarlar: | Demir, Özge Ulusoy, Halil İbrahim Bursa Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü. Özer, Elif Tümay Osman, Bilgen AAI-3137-2021 ABF-4791-2020 37047586000 15221651200 |
Anahtar kelimeler: | Chemistry Carbamate pesticides Solid phase extraction Polymeric microbeads HPLC Performance liquid-chromatography Multiwalled carbon nanotubes Mass-spectrometry Trace levels Microextraction Samples Preconcentration Insecticides Phthalate Nanocomposite |
Yayın Tarihi: | 20-Tem-2020 |
Yayıncı: | Elsevier |
Atıf: | Demir, Ö. vd. (2020). "Development of a new solid phase extraction method for sensitive determination of some carbamate pesticides in water using poly(EGDMA-MATrp) microbeads". Microchemical Journal, 158. |
Özet: | In this work, poly(ethylene glycol dimethacrylate-N-methacryloyl-L-tryptophan methyl ester) [poly(EGDMA-MATrp)] microbeads (average diameter = 106-300 mu m), were synthesized by suspension polymerization technique. The microbeads showed strong affinity and allowed for solid phase extraction (SPE) of two common pesticides; pirimicarb and propoxur in environmental water samples. Some SPE process parameters such as the desorption solvent type, solvent volume, pH and salt concentration were optimized. When it was coupled with high pressure liquid chromatography (HPLC-PDA) for the determination of analytes, the linear ranges were about 10-800 ng mL(-1) and the detection limits were 0.95-2.85 ng mL(-1). Also the correlation coefficients (0.9949-0.9991) and precisions (2.15-2.52% RSD, n = 3) were determined. The technique was also applied to the enrichment of these pesticides in various environmental water samples. However, no target analyte was detected in the samples. Therefore, samples were spiked and recovery values were obtained in the range of 95.8-104.2% with RSDs of 2.6-6.6%. |
URI: | https://doi.org/10.1016/j.microc.2020.105317 https://linkinghub.elsevier.com/retrieve/pii/S0026265X20312510 http://hdl.handle.net/11452/30602 |
ISSN: | 0026-265X 1095-9149 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.