Başlık: | The effect of anterior chamber maintainer on anterior chamber contamination |
Yazarlar: | Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı. Baykara, Mehmet Özakın, Cüneyt Doğru, Murat Ertürk, Haluk Heper, Yasemin Özçetin, Hikmet ABI-7051-2020 AAH-6506-2021 23093006700 57200678942 7006540932 7003716972 56191003300 6603402155 |
Anahtar kelimeler: | Ophthalmology Phacoemulsification Anterior chamber contamination Anterior chamber maintainer Cataract-surgery Surgical technique |
Yayın Tarihi: | 2003 |
Yayıncı: | Sage Publications |
Atıf: | Baykara, M. vd. (2003). “The effect of anterior chamber maintainer on anterior chamber contamination”. European Journal of Ophthalmology, 13(9-10), 770-772. |
Özet: | PURPOSE. To evaluate the effect of anterior chamber continuous infusion maintainer system on the contamination of anterior chamber in phacoemulsification surgery. METHODS. Clear corneal phacoemulsification surgery was performed in 132 eyes of 132 randomly selected patients with cataract who were divided into two groups of 66 eyes according to the use of an anterior chamber maintainer (ACM) system. The fluid specimens were taken from anterior chamber in the beginning and at the end of the surgery. They were transferred under anaerobic conditions and investigated by culturing onto blood agar and thiogluconate broth media. Differences between the two groups with respect to contamination of the specimens were investigated. RESULTS. The mean age of the group undergoing surgery without a maintainer system (Group A) was 63 +/- 10 years (min = 41, max = 80) versus 59 +/- 10 years (min = 33, max = 80) in the other group (Group B) in which the maintainer was used during surgery. In the postoperative specimen, Micrococcus species were isolated from one eye (1.5%) in Group A and S. pyogenes in one eye (1.5%) from Group B. Mean follow-up interval was 12 +/- 6 (min = 4, max 28) months. CONCLUSIONS. The use of ACM system in clear corneal phacoemulsification surgery carries no additional risks as far as contamination is concerned. |
URI: | https://doi.org/10.1177/1120672103013009-1006 https://journals.sagepub.com/doi/10.1177/1120672103013009-1006 http://hdl.handle.net/11452/31357 |
ISSN: | 1120-6721 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Bu öğeyle ilişkili dosya bulunmamaktadır.
DSpace'deki bütün öğeler, aksi belirtilmedikçe, tüm hakları saklı tutulmak şartıyla telif hakkı ile korunmaktadır.