Başlık: | Determination of optimum insulation thickness for different insulation applications considering condensation |
Yazarlar: | Bademli̇oğlu, Ali Hüsnü Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü. Kaynaklı, Ömer Ufat, Hande Tüfekçi AAK-4166-2021 8387145900 57195235906 |
Anahtar kelimeler: | Engineering Building outer wall Condensation Optimization Building walls External walls Climate zones Respect Turkey China Roof Condensation Mass transfer Optimization Space heating Walls (structural partitions) Heat and mass transfer Humidity conditions Indoor temperature Insulation applications Insulation thickness Optimum insulation thickness Outdoor temperature Structural component Thermal insulation |
Yayın Tarihi: | May-2018 |
Yayıncı: | Univ Osijek |
Atıf: | Kaynaklı, Ö. vd. (2018). ''Determination of optimum insulation thickness for different insulation applications considering condensation''. Tehnicki Vjesnik, 25(Supplement 1), 32-42. |
Özet: | In this study, thermal insulation thickness used in the outer walls of buildings composing of different insulation applications having the same thermal resistance was optimized by considering condensation. The minimum insulation thickness required to prevent condensation (i.e. optimum insulation thickness) in building structural component was determined. Heat and mass transfer calculations within the structural component were performed with respect to various indoor-outdoor temperature and relative humidity values and results were given in graphs. It was observed that optimum insulation thickness is generally increased with an increase in the indoor temperature, indoor relative humidity and outdoor relative humidity. It was concluded that type of insulation application does not significantly affect optimum insulation thickness at low and medium level (Theta<0.60) indoor relative humidity conditions. It was also observed that externally insulated wall application generally yields better results at high indoor and outdoor relative humidity conditions. |
URI: | https://doi.org/10.17559/TV-20160402130509 https://hrcak.srce.hr/200595 http://hdl.handle.net/11452/34602 |
ISSN: | 1330-3651 1848-6339 |
Koleksiyonlarda Görünür: | Scopus Web of Science |
Bu öğenin dosyaları:
Dosya | Açıklama | Boyut | Biçim | |
---|---|---|---|---|
Kaynaklı_vd_2018.pdf | 1.11 MB | Adobe PDF | Göster/Aç |
Bu öğe kapsamında lisanslı Creative Commons License