dc.identifier.citation | Ufat, H. vd. (2018). ''Investigation of the number of particles in an operating room at different ambient temperatures and inlet velocities''. International Journal of Ventilation, 17(3), 209-223. | en_US |
dc.identifier.issn | 1473-3315 | - |
dc.identifier.issn | 2044-4044 | - |
dc.identifier.uri | https://doi.org/10.1080/14733315.2017.1392107 | - |
dc.identifier.uri | https://www.tandfonline.com/doi/full/10.1080/14733315.2017.1392107 | - |
dc.identifier.uri | http://hdl.handle.net/11452/34761 | - |
dc.description.abstract | This study presents some field measurements in an operating room of air velocity, ambient temperature and particle counts on the operating table. Moreover, computational fluid Dynamics analyses of the operating room were performed and compared with the measurements. Measurements were taken under the preferred operating conditions by surgical staff (at 19 degrees C) and then at different ambient temperatures (from 20 to 22 degrees C, varying by one-degree increments) and average inlet air velocities (V-j) (0.1 and 0.2 m/s). The preferred one by surgical staff is 0.1 m/s and the maximum that can be reached is 0.2 m/s, with the current system. The results show that the particle count decreased at V-j of 0.2 m/s and low temperatures. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Taylor & Francis | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Construction & building technology | en_US |
dc.subject | Energy & fuels | en_US |
dc.subject | Indoor air quality | en_US |
dc.subject | Operating room air conditioning | en_US |
dc.subject | Particle counting | en_US |
dc.subject | Operating room | en_US |
dc.subject | Laminar air-flow | en_US |
dc.subject | Ventilation performance | en_US |
dc.subject | Indoor environment | en_US |
dc.subject | Airborne infection | en_US |
dc.subject | Thermal comfort | en_US |
dc.subject | Quality | en_US |
dc.subject | Theater | en_US |
dc.subject | Contamination | en_US |
dc.subject | System | en_US |
dc.subject | Staff | en_US |
dc.subject | Air conditioning | en_US |
dc.subject | Air quality | en_US |
dc.subject | Computational fluid dynamics | en_US |
dc.subject | Indoor air pollution | en_US |
dc.subject | Operating rooms | en_US |
dc.subject | Surgery | en_US |
dc.subject | Temperature | en_US |
dc.subject | Air velocities | en_US |
dc.subject | Computational fluid dynamics analysis | en_US |
dc.subject | Field measurement | en_US |
dc.subject | Indoor air quality | en_US |
dc.subject | Low temperatures | en_US |
dc.subject | Operating condition | en_US |
dc.subject | Particle counting | en_US |
dc.subject | Particle counts | en_US |
dc.subject | Air | en_US |
dc.title | Investigation of the number of particles in an operating room at different ambient temperatures and inlet velocities | en_US |
dc.type | Article | en_US |
dc.identifier.wos | 000443028000005 | tr_TR |
dc.identifier.scopus | 2-s2.0-85032699247 | tr_TR |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.contributor.department | Uludağ Üniversitesi/Mühendislik Mimarlık Fakültesi/Makine Mühendisliği Bölümü. | tr_TR |
dc.relation.bap | OUAP (M) 2013/2 | tr_TR |
dc.identifier.startpage | 209 | tr_TR |
dc.identifier.endpage | 223 | tr_TR |
dc.identifier.volume | 17 | tr_TR |
dc.identifier.issue | 3 | tr_TR |
dc.relation.journal | International Journal of Ventilation | en_US |
dc.contributor.buuauthor | Ufat, Hande | - |
dc.contributor.buuauthor | Kaynaklı, Ömer | - |
dc.contributor.buuauthor | Yamankaradeniz, Nurettin | - |
dc.contributor.buuauthor | Yamankaradeniz, Recep | - |
dc.contributor.researcherid | AAA-1753-2021 | tr_TR |
dc.contributor.researcherid | AAK-4166-2021 | tr_TR |
dc.subject.wos | Construction & building technology | en_US |
dc.subject.wos | Energy & fuels | en_US |
dc.indexed.wos | SCIE | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.wos.quartile | Q4 | en_US |
dc.contributor.scopusid | 8387145900 | tr_TR |
dc.contributor.scopusid | 57195235906 | tr_TR |
dc.contributor.scopusid | 26645227400 | tr_TR |
dc.contributor.scopusid | 6507733785 | tr_TR |
dc.subject.scopus | Airborne Infection; COVID-19; Operating Rooms | en_US |
Appears in Collections: | Scopus Web of Science |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.