Please use this identifier to cite or link to this item: http://hdl.handle.net/11452/34944
Title: The value of bedside ocular ultrasound assessment of optic nerve sheath diameter in the detection of increased intracranial pressure in patients presenting to the emergency room with headache
Authors: Uludağ Üniversitesi/Tıp Fakültesi/Acil Tıp Anabilim Dalı.
0000-0003-2271-5659
Çanakçı, Y.
Durak, Vahide Aslıhan
Köksal, Özlem
AAE-9483-2021
Y-3674-2018
AAK-8332-2020
23389880200
55792633100
57202469914
Keywords: General & internal medicine
Headache
Intracranial hypertension
Ocular ultrasound
Optic nerve sheath diameter
Ultrasonography
Management
Physicians
Accuracy
Hypertension
Sonography
Diagnosis
Issue Date: Jun-2018
Publisher: Wolters Luver Medknow Publications
Citation: Çanakçı, Y. vd. (2018). ''The value of bedside ocular ultrasound assessment of optic nerve sheath diameter in the detection of increased intracranial pressure in patients presenting to the emergency room with headache''. Nigerian Journal of Clinical Practice, 21(6), 778-782.
Abstract: Introduction: Headache is one of the most important complaints in emergency room (ER) admissions, and the rate of the increase in intracranial pressure in these cases should not be overlooked. This study was performed to investigate the value of the measurement of optic nerve sheath diameter (ONSD) by ocular ultrasound in ER patients with the complaint of headache and increase in intracranial pressure regarding this. Materials and Methods: A total of 100 patients who applied to the ER with the complaint of headache were included in this prospective study. Fifty patients with increased ONSD (= 5 mm) and 50 patients with normal ONSD (< 5 mm) were obtained. ONSD measurements were performed with 7.5-10 MHz linear probe and closed-eye technique. In addition to this, all patients underwent cranial computerized tomography (CT) examinations, and CT results were compared with the results of the ocular ultrasound. Results: The median right and left ONSD values were detected to be 4.3 mm (3.6-5.5 mm) and 4.4 mm (3.6-5.6 mm) in patients whose cranial CT results were within normal limits. However, the median right and left ONSD values were detected to be 5.5 mm (5.1-6.3 mm) and 5.5 mm (5.1-6.4 mm) in patients whose cranial CT examination results were abnormal. In all cases with abnormal CT findings, the right and the left ONSD measurements were significantly higher (P < 0.001). Furthermore, ONSD value in the ipsilateral side with the lesion was significantly higher than the contralateral side (P < 0.001). Conclusion: Bedside ocular ultrasound is a noninvasive and easily applicable method in ER for the detection and evaluation of intracranial hypertension with headache.
URI: https://doi.org/10.4103/njcp.njcp_119_17
https://journals.lww.com/njcp/fulltext/2018/21060/the_value_of_bedside_ocular_ultrasound_assessment.16.aspx
http://hdl.handle.net/11452/34944
ISSN: 1119-3077
Appears in Collections:Scopus
Web of Science

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.